{"id":4984,"date":"2023-10-13T16:17:25","date_gmt":"2023-10-13T13:17:25","guid":{"rendered":"https:\/\/mitsis.com.gr\/?p=4984"},"modified":"2023-10-12T17:57:06","modified_gmt":"2023-10-12T14:57:06","slug":"solenoid-valve-and-working-principles","status":"publish","type":"post","link":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/","title":{"rendered":"What is a solenoid valve and what are their working principles?"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">A <a href=\"https:\/\/mitsis.com.gr\/en\/solenoid-air-valves\/\">solenoid valve<\/a> is a type of valve that is controlled by an electric current. It uses a solenoid, which is an electromagnetic coil, to open or close the valve. When an electric current is passed through the solenoid, it creates a magnetic field that pulls on a plunger, which in turn opens the valve. When the electric current is turned off, the magnetic field disappears and the plunger is pushed back into place by a spring, closing the valve.<\/span><\/p>\n<h2><strong>Working Principles of Solenoid Valves<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Solenoid valves can be either direct-acting or pilot-operated. Direct-acting solenoid valves are relatively simple in design and are used for low-pressure applications. Pilot-operated solenoid valves are more complex in design, but they can handle higher pressures and flows.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Direct-acting solenoid valves have a plunger that is directly connected to the valve seat. When the solenoid is energized, the plunger is pulled open, allowing fluid to flow through the valve. When the solenoid is de-energized, the plunger is pushed closed by a spring, blocking the flow of fluid.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Pilot-operated solenoid valves use a small pilot valve to control a larger main valve. When the solenoid is energized, it opens the pilot valve, which allows pressurized fluid to flow into the main valve chamber. This pressurized fluid forces the main valve open. When the solenoid is de-energized, the pilot valve closes, blocking the flow of pressurized fluid into the main valve chamber. This allows the main valve to close under the pressure of the fluid downstream.<\/span><\/p>\n<h2><strong>Types of Solenoid Valves<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">There are many different types of solenoid valves, but some of the most common include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Direct-acting solenoid valves:<\/b><span style=\"font-weight: 400;\"> These valves are relatively simple in design and are used for low-pressure applications. Pilot-operated solenoid valves are more complex in design, but they can handle higher pressures and flows.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pilot-operated solenoid valves:<\/b><span style=\"font-weight: 400;\"> These valves use a small pilot valve to control a larger main valve.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Normally open (NO) valves:<\/b><span style=\"font-weight: 400;\"> These valves are open by default and close when the solenoid is energized.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Normally closed (NC) valves:<\/b><span style=\"font-weight: 400;\"> These valves are closed by default and open when the solenoid is energized.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Three-way valves:<\/b><span style=\"font-weight: 400;\"> These valves have three ports and can be used to control the flow of fluid between two ports or to block the flow of fluid altogether.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Four-way valves:<\/b><span style=\"font-weight: 400;\"> These valves have four ports and can be used to control the flow of fluid between any two ports or to block the flow of fluid altogether.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Solenoid valves can also be classified by the type of fluid they control, such as air, water, hydraulic fluid, or steam.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Here is a more detailed explanation of each type of solenoid valve:<\/span><\/p>\n<h3><strong>Direct-acting solenoid valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Direct-acting solenoid valves use the electromagnetic force generated by the solenoid to directly open and close the valve. This type of valve is relatively simple in design and is used for low-pressure applications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Direct-acting solenoid valves have a plunger that is directly connected to the valve seat. When the solenoid is energized, the plunger is pulled open, allowing fluid to flow through the valve. When the solenoid is de-energized, the plunger is pushed closed by a spring, blocking the flow of fluid.<\/span><\/p>\n<h3><strong>Pilot-operated solenoid valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Pilot-operated solenoid valves use a small pilot valve to control a larger main valve. This type of valve is more complex in design than direct-acting solenoid valves, but it can handle higher pressures and flows.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Pilot-operated solenoid valves work by using the pressure of the fluid being controlled to open and close the main valve. When the solenoid is energized, it opens the pilot valve, which allows pressurized fluid to flow into the main valve chamber. This pressurized fluid forces the main valve open. When the solenoid is de-energized, the pilot valve closes, blocking the flow of pressurized fluid into the main valve chamber. This allows the main valve to close under the pressure of the fluid downstream.<\/span><\/p>\n<h3><strong>Normally open (NO) valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Normally open (NO) solenoid valves are open by default and close when the solenoid is energized. These valves are commonly used in applications where the flow of fluid needs to be stopped quickly, such as in emergency shutoff systems.<\/span><\/p>\n<h3><strong>Normally closed (NC) valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Normally closed (NC) solenoid valves are closed by default and open when the solenoid is energized. These valves are commonly used in applications where the flow of fluid needs to be started quickly, such as in irrigation systems.<\/span><\/p>\n<h3><strong>Three-way valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Three-way solenoid valves have three ports and can be used to control the flow of fluid between two ports or to block the flow of fluid altogether. These valves are commonly used in applications where the flow of fluid needs to be diverted, such as in mixing valves or selector valves.<\/span><\/p>\n<h3><strong>Four-way valves<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Four-way solenoid valves have four ports and can be used to control the flow of fluid between any two ports or to block the flow of fluid altogether. These valves are commonly used in applications where the flow of fluid needs to be controlled in two directions, such as in pneumatic cylinders and actuators.<\/span><\/p>\n<h2><strong>Applications of solenoid valves<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Solenoid valves are used in a wide variety of applications, including:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Industrial automation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">HVAC<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Irrigation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Food and beverage processing<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Medical<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Aerospace<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Automotive<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Marine<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">And many more<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Solenoid valves are versatile and reliable components that can be used to control the flow of fluids in a wide range of applications.<\/span><\/p>\n<h2><strong>Application Industries of Solenoid Valves<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Solenoid valves are used in a wide variety of industries, including:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Industrial automation:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are used in industrial automation applications to control the flow of fluids in machinery and equipment.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>HVAC:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are used in HVAC systems to control the flow of water, refrigerant, and air.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Irrigation:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are used in irrigation systems to control the flow of water to sprinklers and other irrigation devices.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Food and beverage:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are used in food and beverage processing to control the flow of fluids such as water, milk, and juice.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Medical:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are used in medical devices such as MRI machines and dialysis machines to control the flow of fluids.<\/span><\/li>\n<\/ul>\n<h2><strong>FAQ<\/strong><\/h2>\n<h3><strong>What are the benefits of using solenoid valves?<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Solenoid valves offer a number of benefits, including:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Fast and reliable operation:<\/b><span style=\"font-weight: 400;\"> Solenoid valves can open and close very quickly, making them ideal for applications where precise control is required.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Low power consumption:<\/b><span style=\"font-weight: 400;\"> Solenoid valves require very little power to operate, making them energy-efficient.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Long service life:<\/b><span style=\"font-weight: 400;\"> Solenoid valves are built to last and can withstand many years of operation.<\/span><\/li>\n<\/ul>\n<h3><strong>What are the limitations of solenoid valves?<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">Solenoid valves have some limitations, such as:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Cost:<\/b><span style=\"font-weight: 400;\"> Solenoid valves can be more expensive than other types of valves, such as manual valves.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Noise:<\/b><span style=\"font-weight: 400;\"> Solenoid valves can produce a clicking noise when they operate.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Flow capacity:<\/b><span style=\"font-weight: 400;\"> Solenoid valves have a limited flow capacity, so they may not be suitable for high-flow applications.<\/span><\/li>\n<\/ul>\n<h3><strong>How do I choose the right solenoid valve for my application?<\/strong><\/h3>\n<p><span style=\"font-weight: 400;\">When choosing a solenoid valve, there are a number of factors to consider, such as:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Type of fluid:<\/b><span style=\"font-weight: 400;\"> The type of fluid being controlled will determine the materials used in the valve and the type of seal required.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Flow rate:<\/b><span style=\"font-weight: 400;\"> The flow rate required will determine the size and type of valve needed.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Pressure rating:<\/b><span style=\"font-weight: 400;\"> The pressure rating of the valve must be higher than the maximum pressure of the fluid being controlled.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Voltage:<\/b><span style=\"font-weight: 400;\"> The solenoid voltage must match the voltage of the power supply.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Environmental conditions:<\/b><span style=\"font-weight: 400;\"> The valve must be able to withstand the environmental conditions of the application, such as temperature, humidity, and vibration.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Remember to <a href=\"https:\/\/mitsis.com.gr\/en\/contact-us\/\">consult an industry expert<\/a> when it comes to <a href=\"https:\/\/mitsis.com.gr\/en\/air-compression-systems-pneumax\/\">pneumatic components<\/a> so he can help you find the perfect fit for depending on your needs and operation systems<\/span><\/p>\n<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/mitsis.com.gr\/en\/air-valves-pneumax\/\"><strong>Air valves<\/strong><\/a> are devices that control the flow of air into or out of a system. They are used in a wide variety of applications, including plumbing, HVAC, and industrial processes.<\/span><\/p>\n<p><br style=\"font-weight: 400;\" \/><br style=\"font-weight: 400;\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A solenoid valve is a type of valve that is controlled by an electric current. It uses a solenoid, which is an electromagnetic coil, to open or close the valve. When an electric current is passed through the solenoid, it creates a magnetic field that pulls on a plunger, which in turn opens the valve.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[126],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What is a solenoid valve and what are their working principles?<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is a solenoid valve and what are their working principles?\" \/>\n<meta property=\"og:description\" content=\"A solenoid valve is a type of valve that is controlled by an electric current. It uses a solenoid, which is an electromagnetic coil, to open or close the valve. When an electric current is passed through the solenoid, it creates a magnetic field that pulls on a plunger, which in turn opens the valve.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\" \/>\n<meta property=\"og:site_name\" content=\"\u039c\u0397\u03a4\u03a3\u0397\u03a3 \u03a0\u039d\u0395\u03a5\u039c\u0391\u03a4\u0399\u039a\u0391 \u03a3\u03a5\u03a3\u03a4\u0397\u039c\u0391\u03a4\u0391\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-13T13:17:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-12T14:57:06+00:00\" \/>\n<meta name=\"author\" content=\"mitsis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"mitsis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\"},\"author\":{\"name\":\"mitsis\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/3b842bf6f2171f097ee40b619c9c464f\"},\"headline\":\"What is a solenoid valve and what are their working principles?\",\"datePublished\":\"2023-10-13T13:17:25+00:00\",\"dateModified\":\"2023-10-12T14:57:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\"},\"wordCount\":1327,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/#organization\"},\"articleSection\":[\"Blog\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\",\"url\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\",\"name\":\"What is a solenoid valve and what are their working principles?\",\"isPartOf\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/#website\"},\"datePublished\":\"2023-10-13T13:17:25+00:00\",\"dateModified\":\"2023-10-12T14:57:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae\",\"item\":\"https:\/\/mitsis.com.gr\/en\/home-page\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is a solenoid valve and what are their working principles?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#website\",\"url\":\"https:\/\/mitsis.com.gr\/en\/\",\"name\":\"\u039c\u0397\u03a4\u03a3\u0397\u03a3 \u03a0\u039d\u0395\u03a5\u039c\u0391\u03a4\u0399\u039a\u0391 \u03a3\u03a5\u03a3\u03a4\u0397\u039c\u0391\u03a4\u0391\",\"description\":\"Mitsis.com.gr\",\"publisher\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/mitsis.com.gr\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#organization\",\"name\":\"\u03a0\u03bd\u03b5\u03c5\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac \u03a3\u03c5\u03c3\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03c5\u03b4\u03c1\u03b1\u03c5\u03bb\u03b9\u03ba\u03ac, \u03c0\u03b9\u03ad\u03c3\u03b5\u03c9\u03c2, \u03bb\u03b1\u03b4\u03b9\u03bf\u03cd \u039c\u03ae\u03c4\u03c3\u03b7\u03c2\",\"url\":\"https:\/\/mitsis.com.gr\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/mitsis.com.gr\/wp-content\/uploads\/2020\/07\/mitsis_logo3.png\",\"contentUrl\":\"https:\/\/mitsis.com.gr\/wp-content\/uploads\/2020\/07\/mitsis_logo3.png\",\"width\":661,\"height\":109,\"caption\":\"\u03a0\u03bd\u03b5\u03c5\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac \u03a3\u03c5\u03c3\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03c5\u03b4\u03c1\u03b1\u03c5\u03bb\u03b9\u03ba\u03ac, \u03c0\u03b9\u03ad\u03c3\u03b5\u03c9\u03c2, \u03bb\u03b1\u03b4\u03b9\u03bf\u03cd \u039c\u03ae\u03c4\u03c3\u03b7\u03c2\"},\"image\":{\"@id\":\"https:\/\/mitsis.com.gr\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/3b842bf6f2171f097ee40b619c9c464f\",\"name\":\"mitsis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/f40254b28659e645af610b6af52793f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/f40254b28659e645af610b6af52793f7?s=96&d=mm&r=g\",\"caption\":\"mitsis\"},\"url\":\"https:\/\/mitsis.com.gr\/en\/author\/mitsis\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is a solenoid valve and what are their working principles?","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/","og_locale":"en_US","og_type":"article","og_title":"What is a solenoid valve and what are their working principles?","og_description":"A solenoid valve is a type of valve that is controlled by an electric current. It uses a solenoid, which is an electromagnetic coil, to open or close the valve. When an electric current is passed through the solenoid, it creates a magnetic field that pulls on a plunger, which in turn opens the valve.","og_url":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/","og_site_name":"\u039c\u0397\u03a4\u03a3\u0397\u03a3 \u03a0\u039d\u0395\u03a5\u039c\u0391\u03a4\u0399\u039a\u0391 \u03a3\u03a5\u03a3\u03a4\u0397\u039c\u0391\u03a4\u0391","article_published_time":"2023-10-13T13:17:25+00:00","article_modified_time":"2023-10-12T14:57:06+00:00","author":"mitsis","twitter_card":"summary_large_image","twitter_misc":{"Written by":"mitsis","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#article","isPartOf":{"@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/"},"author":{"name":"mitsis","@id":"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/3b842bf6f2171f097ee40b619c9c464f"},"headline":"What is a solenoid valve and what are their working principles?","datePublished":"2023-10-13T13:17:25+00:00","dateModified":"2023-10-12T14:57:06+00:00","mainEntityOfPage":{"@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/"},"wordCount":1327,"commentCount":0,"publisher":{"@id":"https:\/\/mitsis.com.gr\/en\/#organization"},"articleSection":["Blog"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/","url":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/","name":"What is a solenoid valve and what are their working principles?","isPartOf":{"@id":"https:\/\/mitsis.com.gr\/en\/#website"},"datePublished":"2023-10-13T13:17:25+00:00","dateModified":"2023-10-12T14:57:06+00:00","breadcrumb":{"@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/mitsis.com.gr\/en\/solenoid-valve-and-working-principles\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u0391\u03c1\u03c7\u03b9\u03ba\u03ae","item":"https:\/\/mitsis.com.gr\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"What is a solenoid valve and what are their working principles?"}]},{"@type":"WebSite","@id":"https:\/\/mitsis.com.gr\/en\/#website","url":"https:\/\/mitsis.com.gr\/en\/","name":"\u039c\u0397\u03a4\u03a3\u0397\u03a3 \u03a0\u039d\u0395\u03a5\u039c\u0391\u03a4\u0399\u039a\u0391 \u03a3\u03a5\u03a3\u03a4\u0397\u039c\u0391\u03a4\u0391","description":"Mitsis.com.gr","publisher":{"@id":"https:\/\/mitsis.com.gr\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/mitsis.com.gr\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/mitsis.com.gr\/en\/#organization","name":"\u03a0\u03bd\u03b5\u03c5\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac \u03a3\u03c5\u03c3\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03c5\u03b4\u03c1\u03b1\u03c5\u03bb\u03b9\u03ba\u03ac, \u03c0\u03b9\u03ad\u03c3\u03b5\u03c9\u03c2, \u03bb\u03b1\u03b4\u03b9\u03bf\u03cd \u039c\u03ae\u03c4\u03c3\u03b7\u03c2","url":"https:\/\/mitsis.com.gr\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mitsis.com.gr\/en\/#\/schema\/logo\/image\/","url":"https:\/\/mitsis.com.gr\/wp-content\/uploads\/2020\/07\/mitsis_logo3.png","contentUrl":"https:\/\/mitsis.com.gr\/wp-content\/uploads\/2020\/07\/mitsis_logo3.png","width":661,"height":109,"caption":"\u03a0\u03bd\u03b5\u03c5\u03bc\u03b1\u03c4\u03b9\u03ba\u03ac \u03a3\u03c5\u03c3\u03c4\u03ae\u03bc\u03b1\u03c4\u03b1 \u03c5\u03b4\u03c1\u03b1\u03c5\u03bb\u03b9\u03ba\u03ac, \u03c0\u03b9\u03ad\u03c3\u03b5\u03c9\u03c2, \u03bb\u03b1\u03b4\u03b9\u03bf\u03cd \u039c\u03ae\u03c4\u03c3\u03b7\u03c2"},"image":{"@id":"https:\/\/mitsis.com.gr\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/3b842bf6f2171f097ee40b619c9c464f","name":"mitsis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/mitsis.com.gr\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/f40254b28659e645af610b6af52793f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f40254b28659e645af610b6af52793f7?s=96&d=mm&r=g","caption":"mitsis"},"url":"https:\/\/mitsis.com.gr\/en\/author\/mitsis\/"}]}},"_links":{"self":[{"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/posts\/4984"}],"collection":[{"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/comments?post=4984"}],"version-history":[{"count":2,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/posts\/4984\/revisions"}],"predecessor-version":[{"id":4986,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/posts\/4984\/revisions\/4986"}],"wp:attachment":[{"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/media?parent=4984"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/categories?post=4984"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mitsis.com.gr\/en\/wp-json\/wp\/v2\/tags?post=4984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}