Hydraulic Valves

Contents

Electromagnetic Hydraulic Valves

Because the viscosity of hydraulic oil varies with temperature (as do the clearances between a valve's moving parts), the output of a control valve can tend to drift with temperature changes, temperature compensators adjust the control orifice openings to correct the results of viscosity changes caused by fluid temperature variations.

Flow control valves regulate the flow of oil through the circuit in one direction while allowing free flow in the opposite direction using a control valve.

P. MITSIS SA specializes in oil pressure systems as the Company dates back to 1972 which can provide solutions and understand your needs which will allow you to meet the increasingly difficult challenges we all face.

The hydraulic products are used by genuine equipment manufacturers active in various sectors, such as shipping constructions, underwater works.

The demanding operation of machinery manufacturing systems and hydraulic units needed to improve productivity and performance have made us gain a technical advantage over the competition by developing a range of products and services.

Cetop 3 (Ng6) High Pressure Oil Solenoid Valves.

Maximum Pressure: 315 Bar
Maximum Supply: 80 Liters

Cetop 5 (Ng10) High Pressure Oil Valves.

Valve Basis. 

Maximum Pressure 315 Bar
Maximum Supply 120 Litres

Control valves for hydraulic systems with one or two electric coils.

 

Proportional High Pressure Oil Valves

Maximum Pressure 315 Bar
Maximum Supply 42 Liters Cetop 3
Maximum Supply 82 Liters Cetop 5

Hydraulic valves analog with integrated electronic card or without, 12-24DC.

Circuits: closed centers. P closed ABT.

 

Cetop 7 (Ng16) High Pressure Oil Solenoid Valves.

High oil pressure hydraulic valves for large supplies.

Maximum Pressure 315 Bar
Maximum Supply 300 Litres

Valves with base for oil circuits and application in large hydraulic assemblies.

Cetop 8 (Ng25) High Pressure Oil Solenoid Valves.

Electromagnetic high pressure oil supply valves over 500 litres.

Maximum Pressure 315 Bar
Maximum Supply 550 Litres

Hydraulic base valves with electric coils for oil command in hydraulic systems for installation in large hydraulic assemblies.

Solenoid Valves with Manual Operation Cetop 3 (Ng6) High Oil Pressure.

High oil pressure electromagnetic valves.

Maximum Pressure 315 Bar
Maximum Supply 40 Litres

Hydraulic base valves with coils electric for oil command for application in small hydraulic units. This valve also has an emergency control in case of power loss.

Cetop 3 (Ng6) High Pressure Oil Solenoid Valves.

High oil pressure hydraulic valves.

Maximum Pressure 315 Bar

Maximum Supply 40 Litres

Hydraulic base valves with electric coils for oil command for application in small hydraulic units. This valve also has an emergency control in case of power loss.

Cetop 5 (Ng10) High Pressure Oil Solenoid Valves.

High oil pressure hydraulic valve.

  • Maximum Pressure 315 Bar
  • Maximum Supply 80 Litres

Hydraulic base valves with coils electric for oil command for application in hydraulic assemblies. This valve also has an emergency control in case of power loss.

High oil pressure hydraulic valves. HYDRAULIC UNITS OF HIGH PRESSURE OIL MITSIS P SA

Proportional Supply Regulator Cetop 3

Hydraulic high pressure oil proportional valve with feedback. 0-24v

  • Maximum Delivery 60 Litres/minute
  • Max Pressure 315 Bar

Analog supply regulator for adjusting the speed of hydraulic cylinders with absolute precision. Possibility of ordering with or without an electronic card. This regulator only has an analog command, not a manual one. When changing the speed of the hydraulic oil, the card has the ability to send information about the speed. so that we change several preset speeds in the same movement of the hydraulic cylinder. 

Nested Regulating Cetop Hydraulic Valves

The inset hydraulic cetop regulating valves are required to regulate the flow and therefore also the speed, pressure regulation (safety) single or double, pressure reduction valves, inset sequence valves, inset overcenter valves to balance the acceleration, but also non-return valves. Finally, there is also an inset valve for speed change with electric command and independent pressure regulator CETOP 3 & CETOP 5

Note: 

All the following valves are (CETOP3 -CETOP5 (NG6-NG10)

VINCKE inset hydraulic valve cetop blue

Insert Valve Provision Setting 

Hydraulic pressure valves for mounting between solenoid valve blocks. In this way, each solenoid valve, i.e. each cylinder, will have its own pressure setting.

Maximum flow: 40 liters

Maximum pressure: 315 bar.

High oil pressure hydraulic valves. HYDRAULIC UNITS OF HIGH PRESSURE OIL MITSIS P SA

Inset Pressure Adjustment Valve

High oil pressure hydraulic valves. HYDRAULIC UNITS OF HIGH PRESSURE OIL MITSIS P SA

Insert Pressure Reducing Valve

High oil pressure hydraulic valves. HYDRAULIC UNITS OF HIGH PRESSURE OIL MITSIS P SA

Inserted Check Valve For Holding Loads

 

 

Insert valve

Inset Overcenter Valve For Load Inertia Retention

 

Insert safety valve with electrical command

Insert Valve: Secures With Electric Command

 

Free Flow Insert Valve

Free Flow Insert Valve

 

Social media & sharing icons powered by UltimatelySocial